AEG 5210 V User Manual

Page 6

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

For the

electrical

installer

Electrical connection

Local and national electrical regulations must be observed.

All instructions given by the Electricity Board must be followed

carefully when connecting the oven to the mains supply,

This is a job for a qualified and approved electrician. The appli-

ance is rated for 240 volts single phase and must be permanently
connected.

The cooker must be installed in such a way that it can be easily
disconnected from the mains supply before servicing, e.g., by an
adjacent cooker oontrol unit.

Sufficient cable should be iett to enable the appliance to be re­
moved from the housing unit whilst still connected to the mains

supply.

WARNING - THIS APPLIANCE MUST BE EARTHED!

Voltage and current

Please ensure that the voltage and current indicated on the rating
plate agrees with the voltage of your electricity supply, 220-240

volts i.e., 220-240 V a.c.

1, Open the cover of the terminal box sideways as illustrated in

fig. G,

'

-

2. Pass cable through the grommet in the lower back panel and

the cable clamp.

3. Connect the wires to the terminals in accordance with the dia­

gram. Ensure that links are correctly positioned between ter­
minals (5 or 6 way terminal block). The length of the earth con­
ductor must be adequate to ensure that in case of the cable
clamp breaking the earth wire is subject to mechanic strain
only after the live wires.