E-Tech VS series 8" submersible pumps User Manual

Page 11

Advertising
background image

11

When flanged pipes are used, the cable clips must be

positioned before and after each flange.

5 .4 Lowering of the pump
Verify that the well is not clogged along its total length.

Lower the pump into the well, paying attention not to

damage the electric cable.

Note: Do not lower the pump by means of the electric

cable.

5 .5 Installation depth
The dynamic water level must always be above the

suction support of the pump, see paragraph 3.1

Positioning Limits and Fig. 5.

The minimum safety margin shall be 1 meter.

Lt

Lc

Ld

La

Lb

Lt

Lc

Ld

La

Lb

001

14015 09/2008

001

14015 06/2010

Fig. 5

La: Minimum installation depth

(suggested: minimum 1 mt).

Lb: Static water level

Lc: Dynamic water level

Ld: Difference between static and dynamic level

Lt: Installation depth

Block the delivery pipe with proper hangers on the well

head.

Loosen the support rope and fix it to the groundwork.

6 . START-UP

When the pump has been installed and submerged, it can

be started with the gate valve closed to 1/3.

Check the direction of rotation as described in section 4.2

Verification of Rotation Direction.

If there are impurities in the water, the gate valve should

be opened gradually until the water becomes clearer. The

pump should not be stopped until the water is completely

clean again, since otherwise the pump parts and the non-

return valve may be damaged.

If the pump flow rate is higher than that of the well,

the use of a protection device against dry operation is

recommended.

Without any protection against dry operation, the water

level falls under the suction support and the pump sucks

air. In the long term, this causes damages due to poor

cooling and lubrication.

7 . MAINTENANCE AND SERVICE

The pumps are maintenance-free.

All pumps are easy to service.

Use the Service Kits and the special tools for maintenance.

The Service Manual is available upon request.

m

Before performing any operation on the pump

or on the motor, verify that the power supply

is disabled and that it cannot accidentally be

enabled again.

8 . DISPOSAL

This product or parts of it must be disposed using the

local public or private waste collection service.

Advertising