9 . TROUBLESHOOTING

Zero flow rate

Poor flow rate

Poor pressure

The pump starts and stops too frequently

Excessive current absorbed by the electro-pump

Possible causes related to the pump

(Motor and panel excluded)

Solution

██ █

Well water level too low

Wait until well water level is restored, or if

possible, lower the pump further

██

Suction screen clogged

Pull out the assembly and clean it

██

Delivery valve closed or blocked

Find and replace the defective valve

█ Pump silted up

Pull out the assembly and clean it

██ █ Wrong direction of rotation

Carry out instructions as in 4.2

█ █

Pump capacity exceeds well capacity

Replace pump with one of lower capacity

Leaks in the system

Locate leaks and repair them

Worn pump

Pull out the assembly and overhaul it

Pressure switch or level control improperly set

Adjust setting

Tank too small

Replace tank with a larger one

█ Mechanical friction

Pull out the pump and overhaul it