2 connection to a suction plant (optional), Start up, 1 turning on the unit – BINDER BD 23 User Manual

Page 23: 2 heating operation display, Caution

Advertising
background image

BD / ED / FD (E2) 02/2015

page 23/63

4.2 Connection to a suction plant (optional)

When directly connecting a suction plant the spatial temperature exactitude, the heating-up and the

recovering times and the maximum temperature will be negatively influenced. So no suction plant should

be directly connected to the exhaust duct.

Active suction from the chamber must only be effected together with extraneous air. Perforate

the connecting piece to the suction device or place an exhaust funnel at some distance to the

exhaust duct.

CAUTION

The exhaust duct will become hot during operation.
Danger of burning.

Do NOT touch the exhaust duct during operation.


5.

Start up

5.1 Turning on the unit

Warming chambers may release odors in the first few days after commissioning. This is not a

quality defect. To reduce odors quickly we recommend heating up the chamber to its nominal

temperature for one day and in a well-ventilated location.

1. Insert the plug into a suitable socket (chap. 4.1).
2. Turn on ED units sizes 400 and 720 at the main power switch (10)

The green “Standby“ LED illuminates

3. Press

until the display lights up.

The controller is now in normal display (actual value display).
If the chamber is operating (time functions “Continuous operation”, or

“Timer operation” with the set time just running down chap. 6.3), the

actual temperature value (example: 22 °C) is displayed

If the controller is in time function “Timer operation” with no time programmed or the set time run-off

(chap. 6.3), the unit is inactive (no heating). The display alternately shows the

actual temperature value

(example: 22 °C) and “

tOff”:

Adjust the safety device following any changes of the set-point (chap. 7).

5.2 Heating operation display

The heating and fan (with FD) are active as soon as the red heating

control light in the bottom right corner of the display slowly begins to

flash depending on the heat requirement (example: 70 °C).


Advertising
This manual is related to the following products: