CIRCUTOR DHB Series User Manual

Page 23

Advertising
background image

23

Table 4

dISP

Parameter

symbol

Description

Range of changes

d_P

Minimal position of the decimal point
when displaying the measured value
- display format. This parameter is not
taken into consideration during the
modes CountH and HoUr.

0.0000 – 0
00.000 – 1
000.00 – 2
0000.0 – 3
00000 –

4

CoLdo

Display colour, when the displayed
value is ower than CoLLo

rEd – red
grEEn – green
orAnG - orange

CoLbE

Display colour, when the displayed
value is higher than CoLLo and lower
than CoLHi

CoLuP

Display colour when the displayed value
is higher than CoLHi

CoLLo

Lower threshold of colour change

-19999..99999

CoLHi

Upper threshold of colour change

-19999..99999

ovrLo

Overflow of lower value of the measuring
range value or the programmed indica-
tion range is signaled on the display by
the

symbol.

-19999..99999

ovrHi

Overflow of upper value of the measur-
ing range value or the programmed
indication range is signaled on the
display by the

symbol.

-19999..99999