8. TECHNICAL DATA

Measuring Ranges.

Table 15

Kind of inputs

Indication range

Class

Number of pulses

Cntr1, Cntr2

-19 999..99 999

1)

±1 pulse

Frequency <10 kHz

0.05...99 999 Hz

2)

0.01

Frequency >10 kHz

1...99 999 kHz

(measuring range up to

1 MHz)

3)

0.01

Rotational speed

0.05...99 999 [Rev/min]

1)

0.01

Period t < 10s

0.0001...11 [s]

1)

0.01

Period t > 10s

0.0001...3600 [s]

1)

0.01

Worktime counter

0...99 999 [h]

0.5 sec/24 hours

Current time

00.00...23.59

0.5 sec/24 hours

Encoder

-19 999...99 999

1)

-

Relay outputs

- relays, NOC voltageless contacts

load capacity 250 V~/0.5A~

-

relays, switched voltageless contacts

load capacity 250 V~/0.5A~

Analog outputs (DHB-124) -programmable, current 0/4..20 mA

load resistance

 500 W

- programmable, voltage 0...10 V

load resistance

 500 W

1)

maximal frequency of input signal with filter :2 kHz ; without filter for Cntr1 input

10 kHz, for Cntr2 input 8 kHz (table 8).

2)

maximal frequency of input signal: 100 kHz; measuring range without filter:10

kHz,

with filter 100Hz.

3)

maximal frequency of input signal: 1MHz,