PT-20 Programming Guide

91

transmitted one by one until the specified number of character is sent. Use

the argument “port” as the connect port which is chosen to open. You can

c

hoose 1(RS232). The argument “count” is the number of words of sending

data.

If you select RS-232 and set hardware flow control(CTS/RTS), this function

will wait while data be transmitted.

Returns: -1 : error

Other value: the number of words that success writing into.

open_com

Purpose: Initialize and enable specified RS232 port

Syntax: int open_com(int com_port, int setting);

Example call: open_com(1,0x0b);/*openCOM1,baud rate 38400,8 data bits,no parity,no

handshake*/

Includes:

#include “SDK.h ”

Description: The open_com function initializes the specified RS-232 port. It clears the

receive buffer, stops any data transmission under going, reset the status of

the port, and set the RS-232 specification according to parameters set. Use

the argument “port” as the connect port which is chosen to open. You can

choose 1(RS232).

Each bit of the argument “setting”:

D0

~

D2

baud rate

0 :115200 1-2 : 57600

3 : 38400 4 : 19200

5 : 9600 6-7 : 4800

D3

data bits

0 : 7bits 1 : 8bits

D4

Parity enable

0 : disable 1 : enable

D5

even / odd

0 : odd 1 : even

D6

flow control

0 : disabe 1 : enable

D7

flow control method

0 : CTS/RTS 1 : Reserved

Returns: 0 : Open fail

1 : Open success

Remark: When flow control set up disable and flow control method set up CTS/RTS.

When you use IR port, the baud rate only can be setted 115200, flow control

disable.

read_com

Purpose: Read 1 byte from the RS232 receive buffer

Syntax: int read_com(int port, char *c);