6 access and execution of a test using xml – Artesyn ViewCheck on ATCA-9405 Installation and Use (November 2014) User Manual

Page 30

Advertising
background image

Installation of ViewCheck

ViewCheck on ATCA-9405 Installation and Use (6806800S51F)

30

show-test-result Show test result

show-test-status Show test status

show-upper-threshold-info Show upper threshold info.

start-monitor Start a monitor

start-test Start a test

stop-monitor Stop a monitor

stop-test Stop a test

After logging into the CLI, you can start, stop, and query a test from the CLI. You can view the
details of the test by executing show-test-help command.

To start a test, you can run start-test command with testId, deviceInstance, and
arguments as input to the command. The arguments can be neglected for tests that does not
take any argument as input.

After test execution, the results can be viewed by show-test-result command, which
displays test result and a raw log generated by that test.

Using CLI, you can list all the InService diagnostics monitors in a device category. By default, all
monitors start when ViewCheck application is initialized. You can start and stop any monitor
using start-monitor and stop-monitor commands.

To exit from the ViewCheck CLI:

BSF(diag-SP_VEE0)#exit

BSF(VEE-vee0)#exit

BSF(config)#exit

#exit

3.6

Access and Execution of a Test Using XML

You can access ViewCheck XML interface similar to ViewCheck CLI.

1. Establish the secure shell using SSH or Putty.

2. Start the Telnet connection from an already established secure shell.

Advertising