6 oosd tests, 1 cpu, Oosd tests – Artesyn ViewCheck on ATCA-9405 Installation and Use (November 2014) User Manual
Page 79
Commands Execution
ViewCheck on ATCA-9405 Installation and Use (6806800S51F)
79
4.6
OOSD Tests
OOSD Tests are used to monitor and manage the performance of the hardware components of
blades. You can execute these tests only when blades are offline, that is blades are not
providing any service. Details of the test is supported on SP or PP or both is mentioned with the
test name.
4.6.1
CPU
CpuBurnTest (SP): This test constantly cycles FPU intensive functions.The resultant
calculations are constantly checked for data integrity. If the test detects erroneous data,
the test fails.
OctBootTest (SP): This test boots the PPs into U-Boot. If the correct U-Boot prompt is
detected, the test is passed.
OctDDR2MemTest (SP): This test executes the hw-ddr2 memory test on Octeons with
ECC check. This includes below set of memory tests:
–
Marching Rows
–
Random Data Test
–
Random XOR Test
–
Self Address Test
–
March C-Solid Bits Test
–
March C-Checkerboard Test
–
Walking Ones Left Test
–
Walking Ones Right Test
–
Walking Zeroes Left Test
Before starting any PP related OOSD diagnostics test, make sure that VLAN interface
(example, eth1.21) reaching octeon is properly configured with an IP.