20 start-diag-scan, Table 4-8, Start-all-monitors – Artesyn ViewCheck on ATCA-9405 Installation and Use (November 2014) User Manual

Page 56: Commands execution

Advertising
background image

Commands Execution

ViewCheck on ATCA-9405 Installation and Use (6806800S51F)

56

The following table provides the start-all-monitors command arguments.

Syntax for XML
<Script>

<InvokeMethod>

<Object>

<Class>diagnostic</Class>

<Name>SP_VEE0</Name>

</Object>

<Method>startAllMonitors</Method>

<Argument>

<Name>device-category</Name>

<Value>{Dev category String}</Value>

</Argument>

</InvokeMethod>

</Script>]]>]]>

4.2.20 start-diag-scan

start-diag-scan

starts the diag-scan on the specified device categories.

Syntax for CLI
start-diag-scan deviceCategory <Dev category-1>,…,<Dev category-N>

Iterations <Itr-num> haltOnError <halt-string> timeout <timeout-

val>

Iterations

, haltonError, and timeout are optional arguments.

Table 4-8 start-all-monitors

Argument

Data Type

Description

Dev category

String

Name of the device category.

Advertising