Installation, Optional wall switch or thermostat installation – Avalon Firestyles Cypress User Manual

Page 11

Advertising
background image

Installation

(for qualified installers only)

11

© Travis Industries

4121130

100-01311

Optional Wall Switch or Thermostat Installation

Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must be

installed by a qualified installer.

Caution:

Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.

Note:

When using a GreenSmart™ remote, use the receiver for on/off operation (do not use a wall
switch or thermostat).

Warning:

Make sure all wiring is secure and does not contact hot or moving components.

The wall switch (or thermostat) may bypass the fireplace on/off switch or be installed in
parallel or series configuration (see below).

Parallel Connection

Series Connection

On / Off Switch

ON

On / Off Switch

OFF

On / Off Switch

ON

On / Off Switch

OFF

Thermostat / External

Switch ON

Heater is ON

Heater is ON

Thermostat /

External Switch ON

Heater is ON

Heater is OFF

Thermostat / External

Switch OFF

Heater is ON

Heater is OFF

Thermostat /

External Switch OFF

Heater is OFF

Heater is OFF

To wire the heater in parallel, follow the directions below:

To wire the heater in series, follow the directions below:

Thermostat

(or External Switch) Wires

a

b

c

On / Off Switch

a

On / Off Switch

c

b

Thermostat

(or External Switch) Wires

Advertising