Installation

(for qualified installers only)

21

© Travis Industries

4121130

100-01311

Top Vent Configuration with Vertical Termination

Use 6-5/8” Diameter Vent

Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel.

A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a
horizontal elbow (see illustration).

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
and diffuser position. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor
position may vary slightly, especially when the termination is near a demarcation line.

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

20 feet (6m)

25 feet (7.5m)

30 feet (9m)

40' max (12m)

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

20 feet (6m)

25 feet (7.5m)

30 feet (9m)

40' max (12m)

10 feet (3m)

15 feet (4.5m)

20 feet (6m)

24 ' max (7.3m)

0 feet

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

20 feet (6m)

24 ' max (7.3m)

35 feet (10.5m)

35 feet (10.5m)

0 feet

Exhaust Restrictor Position #4

Diffuser Open (stock)

Exhaust Restrictor Position #3

Diffuser Closed

Exhaust Restrictor Position #2

Diffuser Closed

Exhaust Restrictor Removed

Diffuser Closed

Horizontal elbows are elbows placed between

two horizontal sections of pipe. One 45° or 90°

horizontal elbow is allowed for this configuration.

Horizontal Elbow