Installation

(for qualified installers only)

© Travis Industries

4121130

100-01311

Approved Vent Configurations

Exhaust Restrictor Position

An exhaust restrictor is built into the appliance to control the flow rate of exhaust gases. This
ensures proper flames for the wide variety of vent configurations. Depending upon the vent
configuration, you may be required to adjust the restrictor position. The charts for approved vent
configurations describe which position the vent restrictor should be in.

NOTE:

If the vent configuration calls for restrictor removal, replace the screws into the holes
in the firebox ceiling to seal the firebox.

Loosen these two screws

on the exhaust restrictor.

Slide the restrictor to the correct

restrictor position (see the illustration

below). The screw location indicates

restrictor position. In this example, the

restrictor is set in position # 3. Tighten

the screws to secure the restrictor.

(closed) # 5

# 4
# 3
# 2

(open - stock position) # 1

Back Wall of Firebo

x

Firebo

x Roof