Installation – Avalon Firestyles Cypress User Manual

Page 18

Advertising
background image

18

Installation

(for qualified installers only)

© Travis Industries

4121130

100-01311

Rear Vent Configuration with Horizontal Termination

Use the rear vent conversion from Travis Industries (SKU 94400998).

Use 8” Diameter Vent

Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel.

A maximum of three (3) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a
horizontal elbow (see illustration).

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary
slightly, especially when the termination is near a demarcation line

Exhaust Restrictor Position #5

Exhaust Restrictor Extender Installed

5 feet (1.5m)

10 feet (3m)

0 feet

5 feet (1.5m)

0 feet

0 feet

10 feet (3m)

0 feet

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

16' max (4.8m)

Min. 1' (0.3m) Vertical Section Required

12 feet max (3.6m)

Exhaust Restrictor Removed

12 feet max (3.6m)

Exhaust Restrictor Position #3

Exhaust Restrictor Extender Installed

5 feet (1.5m)

10 feet (3m)

15 feet (4.5m)

16' max (4.8m)

Horizontal elbows are elbows placed between

two horizontal sections of pipe. One 45° or 90°

horizontal elbow is allowed for this configuration.

Horizontal Elbow