Installation

(for qualified installers only)

17

© Travis Industries

4121130

100-01311

Rear Vent Configuration with No Rise

Use the minimum vent kit “D” from Travis Industries (SKU 96200317). This kit contains the following
components used to vent the stove through a typical exterior wall:

-- Travis Thimble (unique to this stove)
-- Wall Cover (Black)
-- Pipe Section (3.9”)
-- Pipe Section (6”)
-- Snorkel Cap (14” – unique to this stove)
-- Rear Vent Conversion Parts (cover plates, starter sections, etc.)

No elbows (45° or 90°) may be used (no corner installations).

Maximum Horizontal Run of 2’ (additional 8” co-axial vent may be used).

Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel.

Exhaust restrictor must be removed.

Do not install the exhaust restrictor extender.

8" Diameter Vent

Max. 2' (610mm) length

Typical 8-1/2" (216mm)

Min. 12" (305mm)

Grade

Travis Thimble

(unique to this stove)

Travis Snorkel

(unique to this stove)