Installation

(for qualified installers only)

15

© Travis Industries

4121130

100-01311

Closing the Diffuser (for top vent configurations only)

IMPORTANT NOTE: The diffuser can be easily closed with no vent in place. Consult the vent
configuration charts to determine diffuser position. If the diffuser needs to be in the closed position,
adjust the diffuser prior to installing vent.

To close the diffuser, reach into the vent starter section and bend the diffuser back (see photos
below). You may need a screwdriver to bend the upper portion of the diffuser 90° (see photos
below).

Diffuser Open (stock)

Diffuser Closed

Closing the Diffuser After Vent is Installed

 The diffuser may be removed from within the firebox and bent into the closed position . This

requires removal of the burner, fireback shelf, and rear firebox wall (rivet cover). Once removed,
the diffuser may be removed from below, bent 90°, and re-installed. See the illustration below.

Remove the

diffuser.

Before (Stock - Position # 1)

After (Position # 2)

DIFFUSER SIDE VIEW

Bend the round portion of the

diffuser so it is bent (position # 2).

Replace the

diffuser.

The diffuser is found on the inner flue assembly .

Bottom of inner

flue assembly

a

b

c

Inner flue assembly