16 Installation

(for qualified installers only)

© Travis Industries

4140922

100-01410

Electrical Connection

 The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified

installer and must meet all local codes.

 Make sure the household breaker is shut off prior to working on any electrical lines.
 The appliance, when installed, must be electrically grounded in accordance with local codes or, in the

absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.

 The electrical line must be a min. 14 gauge, and supply 120 Volts, 60 Hz, and 5.7 Amps.
 Route the electrical connection through the junction box cover plate and attach to the hookup wires

pictured below.

Caution:

Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.

Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.