Vent Configuration: Vertical Termination

 The termination must fall

within the shaded area
shown in the chart. Use
the indicated restrictor
positions.

 Up to five elbows (45° or

90°) may be used.

 Only one horizontal elbow

may be used.

 6-5/8" (168mm) diameter

Simpson Dura-Vent Model
Direct-Vent Pro (or GS)vent
may be used for this
configuration. Attach a 8”
diameter 45° elbow to the
fireplace, connect a reducer
to the elbow (part #
98900165), then connect 6-
5/8” vent to the reducer.
Use the vertical high wind
cap (46DVA-VCH).

Exhaust Restrictor # 8

Intake Restrictor # 3

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

5 feet (1.5m)

10 feet (3m)

5 feet (1.5m)

10 feet (3m)

0 feet

15 feet (4.5m)

20’ (6m) max

10 feet (3m)

15 feet (4.5m)

15 feet (4.5m)

20’ (6m) max

10 feet (3m)

15 feet (4.5m)

40’ (12m) max

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

40’ (12m) max

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

Exhaust Restrictor # 5

Intake Restrictor # 3

Exhaust Restrictor # 3

Intake Restrictor # 1

Exhaust Restrictor # 1

Intake Restrictor # 1

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1