Installation

(for qualified installers only)

21

© Travis Industries

4140922

100-01410

Vent Configuration: Horizontal Termination (no vertical rise)

NOTE: A Wall thimble (part #58DVA-WT) is required.
 The termination must fall within the shaded area shown in the chart. Use the indicated restrictor

positions.

NOTE: When venting horizontally, use minimum vent kit “C” (

96200316). If venting from a corner

installation, an additional 45° elbow is required.

45 Elbow

Termination

3 feet (0.915m)

0 feet

0 feet

4’ max (1.22m)

Exhaust Restrictor # 1 (stock)

Intake Restrictor # 1 (stock)

Vent with No 45˚ Elbow

3 feet (0.915m)

0 feet

0 feet

2

’ max (0.61m)

Vent with 1 45˚ Elbow

Min. 6" (152mm) Horizontal Section

Max. 24" (610mm) Horizontal Section(s)

Min. 6" (152mm) Horizontal Section

Max.48" (1219mm) Horizontal Section(s)

Exhaust Restrictor # 1 (stock)

Intake Restrictor # 1 (stock)

Optional 45 Elbow