Installation

(for qualified installers only)

19

© Travis Industries

4140922

100-01410

Approved Vent Configurations

Restrictor Position

 Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and

exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.

Exhaust Restrictor

Position 3

(closed) #8

#7

#6

# 5

# 4

# 3

# 2

(open - stock position) # 1

b

b

a

c

Position 3