Installation, Approved vent configurations, Ba c – Avalon Firestyles 864 HO GS2 Installation User Manual
Page 19
Advertising
Installation
(for qualified installers only)
19
© Travis Industries
4140922
100-01410
Approved Vent Configurations
Restrictor Position
Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and
exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.
Exhaust Restrictor
Position 3
(closed) #8
#7
#6
# 5
# 4
# 3
# 2
(open - stock position) # 1
b
b
a
c
Position 3