Installation, Ba c – Avalon Firestyles 864 HO GS2 Installation User Manual

Page 9

Advertising
background image

Installation

(for qualified installers only)

9

© Travis Industries

4140922

100-01410

Fireplace Placement Requirements

 Fireplace must be installed on a level surface capable of supporting the fireplace and vent
 Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
 Fireplace should be located out of traffic and away from furniture and draperies.
 Fireplace must be placed so the gaps below and above the glass frame do not become blocked.
 Fireplace may be placed in a bedroom. Please be aware of the large amount of heat this appliance

produces when determining a location.

Clearances

(a) Clearance to Side and Rear of Fireplace 0” (0mm)

(b) When installed, walls in front of the fireplace must be a minimum 5” (127mm) to the side of the

fireplace. Do not place insulation in this space.

(c) Clearance to Angled Sides of Fireplace ½” (12mm)

Raised Fireplaces

 The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace

and vent.

 The base of the fireplace must be a minimum 70” (1778mm) below the room ceiling.

b

a

c

Advertising