24 Installation

(for qualified installers only)

© Travis Industries

4140922

100-01410

Termination Requirements

!

Venting terminals shall not be recessed into a wall or siding.

A

Minimum 9" (229mm) clearance from any door or window

B

Minimum 12" (305mm) above any grade, veranda, porch, deck or balcony

C

Minimum 1" (25mm) from outside corner walls
NOTE: Clearance in accordance with local installation codes and the requirements
of the gas supplier.

D

Minimum 1" (25mm) from inside corner walls
NOTE: Clearance in accordance with local installation codes and the requirements
of the gas supplier.

E

Minimum 11" (279mm) clearance below unventilated soffits or roof surfaces
Minimum 18" (457mm) clearance below ventilated soffits
Minimum 6" (152mm) clearance below roof eaves
NOTE: Vinyl surfaces require 24" (610mm)
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

F

Minimum 12" (305mm) clearance below a veranda, porch, deck or balcony
NOTE: Permitted only if veranda, porch, deck, or balcony is fully open on a minumum of two sides beneath the floor.
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

G

Minimum 48" (1219mm) clearance from any adjacent building

H

Minimum 84" (2134mm) clearance above any grade when adjacent to public walkways or driveways
NOTE: may not be used over a walkway or driveway shared by an adjacent building

I

Minimum 9" (229mm) clearance to any nonmechanical air supply inlet to the building or the combustion air inlet
to any other appliance.

J

Minimum 36" (914mm) clearance above any mechanical air supply inlet if within 10’ (3M) horizontally

K

Minimum 36" (914mm) from the area above the meter/regulator (vent outlet) - this extends 15’ (4.5M) above the
regulator
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

L

Minimum 36" (914mm) from the meter/regulator (vent outlet)
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

M Minimum 12” (305mm) above the roof line (for vertical terminations)

N

Minimum 24” (610mm) horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

11" Min.

(279mm)

6" Min.
(152mm)

Roof
Surface

Roof
Eaves

C

B

H

E

G

A

D

F

L

K

J

I

NOTE: Measure clearances to the nearest edge of the exhaust hood.

A

E

E

M

N