Installation, For qualified installers only), Clearances – Avalon Firestyles AGP User Manual

Page 10

Advertising
background image

10

Installation

(For Qualified Installers Only)

© Travis Industries

4141230

100-01270

Clearances

Straight Installations

Corner Installations

*

Install the vent at the clearance specified by the vent manufacturer.

NOTE: If an interior vertical vent is used, the stove to backwall dimension is determined by the
vent being used. This dimension will vary depending on the brand of pellet vent used. To
determine the distance from the backwall to the stove, connect the "Tee" and add the vent
clearance.

** The floor protection must extend 2” (51mm) beyond the pipe – all vent clearances must be met.

6” Minimum

6” Minimum

2”

Minimum**

“Tee”

3” Minimum

6” Minimum

Through the Wall Installations

Interior Vertical Vents

Floor Protection

6” Minimum

Vent

Clearance*

Through the Wall Vents

6” Minimum

3” Minimum

45° Elbow

45°

Interior Vertical Vents

3” Minimum

6” Minimum

2”

Minimum*

3”

Minimum

“Tee”

Vent

Clearance*

3” Minimum