Safety

Label 45

© Travis Industries

4141230

100-01270

WARNING - DO NOT REMOVE OR COVER THIS LABEL

Report No. 100517995-001

Control No. 4000515

MODEL: AGP PS

Listed Pelletized Solid Fuel Burning Appliance

Also for use in mobile homes

Certified for US and Canada

SERIAL NO:

Conforms to ASTM E1509-04, Room Heater Pellet Burning Type (UM) 84 HUD; Certified to ULC S627

Electrical Rating: 115 V, 60 Hz, 3 Amp: Start 3 Amps, Run 2.2 Amps with blower on High

Maximum Input Rating: 5.0 lbs/hr
This pellet fired appliance has been tested and listed for use in manufactured (mobile) homes in accordance with OAR 814-23-900 through 814-23-909.
WARNING - FOR MANUFACTURED HOMES: Must utilize outside combustion air inlet (part #99200136) or equivalent. Structural integrity of the manufactured home floor, ceiling and

walls must be maintained.
Install only in accordance with the manufacturer’s installation and operating instructions. Contact local building or fire officials about restrictions and installation inspection in your

area. Use only 3 in. / 77 mm diameter listed type “L” or “PL” venting system. See manufacturer’s installation instructions and local codes for precautions required for passing

chimney through a combustible wall or ceiling. Do not connect this appliance to a chimney flue serving another appliance. Inspect and clean exhaust venting system frequently in

accordance with manufacturer’s instructions.
May be installed in a sleeping room with use of outside combustion air inlet (Part #99200136) or equivalent.

For use with 1/4 in. / 6 mm to 5/16 in. / 7 mm diameter pelletized wood fuels only.

Replace glass only with 5 mm ceramic glass available from your dealer.

DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route power cord away from unit. Do not route power cord beneath heater.

Operate only with viewing door and ash removal tray tightly closed. Do not obstruct combustion air openings. The space beneath heater must not be obstructed. Keep all

furnishings away from heater.

Minimum Clearance to Combustible Materials (Measured to Stove Top)

A
B
C
D

Side wall
Rear wall
Corner
Flue Vent

Interior Vertical

Flue Installation

6 in. / 153 mm

**

3 in. / 77 mm

2 in. / 51 mm **

Horizontal Through

the Wall Installation

6 in. / 153 mm

3 in. / 77 mm
3 in. / 77 mm

2 in. / 51 mm **

B

E

REAR WALL

SIDEW

A

LL

SIDEW

A

LL

D

A

A

F

F

FLOOR PROTECTOR

CORNER

CORNER

C

C

Maximum alcove depth 48 in. / 1220 mm, minimum ceiling height 60 in. / 1524 mm, minimum alcove width 36-9/16 in. / 929 mm.

Combustible floor must be protected by a non-combustible material underneath appliance, extending to the front (E) 6 in. / 150 mm and to the sides (F) 0 in. / 0 mm.

EXCEPTIONS: Non-combustible floor protection must extend beneath a vent tee when installed.

** This dimension will vary depending on brand of listed type “L” vent. See manual for details.

4800 Harbour Pointe Blvd. SW

Mukilteo, WA 98275

Manufactured by:

www.travisproducts.com

U.S. ENVIRONMENTAL PROTECTION AGENCY: Certified to comply with July 1990 particulate emission standards.

2012

2013

2014

Jan.

Feb.

Mar.

Apr.

May

June

July

Aug.

Sep.

Oct.

Nov.

Dec.