Maintenance – Avalon Firestyles AGP User Manual

Page 40

Advertising
background image

40

Maintenance

© Travis Industries

4141230

100-01270

Yearly Maintenance (or Every Ton of Pellets) - Clean the Negative Pressure Tube

1. Disconnect the end of the tube from the combustion blower.

2. Clean the nozzle using a pipe cleaner.

Yearly Maintenance (or Every Ton of Pellets) - Clean the Vent

WHENEVER ANY PORTION OF THE PELLET VENT IS DISCONNECTED, THE JOINTS MUST
BE SEALED WITH RTV 500° F. SILICONE SEALANT, UNLESS OTHERWISE SPECIFIED BY
THE VENT MANUFACTURER.

Check the vent sections for creosote
accumulation (indicating a poorly burning
stove). Accumulation over 1/4” must be
removed.

On vertically vented systems, the dirtiest portion
is often the point where the vent turns upwards
(i.e. the "Tee"). Fortunately, the "Tee" has a built-
in clean-out cover. Place a container under the
“Tee”, disconnect the cover and remove all flyash.
While open, use a flashlight to look up the vent to
check for build-up.

Make sure the cap is free of debris
(especially if it has a screen that could
become blocked).

Flyash will deposit along
sections that are horizontal.

Advertising