Installation, For qualified installers only), Venting the pellet stove – Avalon Firestyles AGP User Manual

Page 11: Maximum venting distance

Advertising
background image

Installation

(For Qualified Installers Only)

11

© Travis Industries

4141230

100-01270

Venting the Pellet Stove

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR

STOVE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND

A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH
CEILINGS (MAKE SURE TO MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).

 No more than one tee and 180° of elbows (one tee with two 90° elbows, one tee with one 90° and

two 45° elbows, etc.).

Maximum Venting Distance

 Vent must have a support bracket

every 5' (1.524 M) of pellet vent
when on exterior of structure.

NOTE: Travis Industries
recommends a minimum vertical
vent of 5’ to ensure adequate draft
during a power outage.

0 F

e

e

t

5 F

e

e

t

10 F

e

e

t

(m

a

x

.)

0 F eet

5 F eet

10 F eet

15 F eet

20 F eet

25 F eet

30 F eet

T he vent height and run

mus t not exceed the

dis tance s hown in the
s haded region s hown to the

right.

NOT E : T o achieve optimum

performance, we

recommend keeping the
vent as s hort as pos s ible

(horizontal run es pecially).

V enting into this s haded

area may require res trictor

adjus tments . S ee the
s ection “R es trictor

Adjus tment” for details .

35 F eet

40 F eet

(max.)