Installation

(For Qualified Installers Only)

15

© Travis Industries

4141230

100-01270

Installation Examples

Installation Example: Direct "Through-the-wall" Installation

NOTE: Travis Industries recommends a minimum vertical vent of 5’ to ensure adequate draft during a
power outage.

Install the vent at the clearance specified by the vent manufacturer.

Floor Protection

House Shield (used to protect

exterior wall from soot

discoloration) is HIGHLY

RECOMMENDED

12” Minimum

Horizontal Rain Cap

Wall Thimble
(note clearance
between vent and
combustibles)

Type "L" Vent

12”

Minimum

3” Minimum

Floor Protection

Seal each vent

section (including

adapters, elbows,

etc...) by injecting a

liberal amount of

500° F. RTV

silicone into the gap

between sections,
unless otherwise
specified by the
manufacturer.

500°

F. R

TV

Sil

ico

ne

3” Minimum

6” Minimum

6” Minimum