Operation – Avalon Firestyles AGP User Manual

Page 26

Advertising
background image

26

Operation

© Travis Industries

4141230

100-01270

Changing the TSTAT Program

This heater comes with three TSTAT programs built in. Each program is unique and allows you to modify your
thermostat setting to your preference. The stove is shipped pre-programmed in TSTAT program 1.

How to Tell Which TSTAT Program You Are In

When you press the “STOP” and “TSTAT” button simultaneously while the unit is cold the blue Auto-Fan LED
light will flash. It will flash once for Program 1, twice for Program 2, and three times for Program 3.

Switching Between Program 1, 2, and 3

Each time you press the “STOP” and “TSTAT” button simultaneously while the unit is cold, the TSTAT program
will toggle to the next program. Continue to press these two buttons until the blue Auto-Fan LED light flashes the
program you wish to use.

Thermostat Program 1

When the thermostat stops calling for heat (the thermostat is open) the thermostat “steps down” to a lower heat
setting. The heater will stay at this setting for 15 minutes. If the thermostat does not call for heat, the thermostat
will “step down” again to a lower setting (or off). At any time if the thermostat calls for heat (thermostat is
closed) during this cycle, the heater will resume at the HEAT output setting set at the control board.

Heater Set at

HIGH

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set on
control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater goes to MEDIUM. If after 15 minutes
thermostat still open, heater goes to MEDIUM-LOW. If
after 15 minutes thermostat still open, heater goes to
LOW. If after 15 minutes thermostat still open, heater
turns off.

Heater Set at

MEDIUM

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set on
control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater goes to MEDIUM-LOW. If after 15 minutes
thermostat still open, heater goes to LOW. If after 15
minutes thermostat still open, heater turns off.

Heater Set at

MEDIUM-LOW

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set on
control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater goes to LOW. If after 15 minutes thermostat
still open, heater turns off.

Heater Set at

LOW

If thermostat calls for heat
(thermostat closed)

Heater runs at setting set on
control panel dial.

If thermostat stops calling for heat (thermostat open)

Heater will run for 15 minutes. If thermostat still open,
heater turns off.

NOTE: This program is not recommended for areas with little heating requirements (mild climates, small
rooms, etc.).

Thermostat Program 2

In Thermostat Mode Program 2 when the thermostat stops calling for heat (the thermostat is open) the
following happens:

The burn rate decreases to Level 1 (low) for 15 minutes. If there is no call for heat during that time…

The unit turns off.

If there is a call for heat by the thermostat (the thermostat is closed) at any point during this cool-down period
then the burn rate resumes corresponding with the setting on the control panel.

Thermostat Program 3

In Thermostat Mode Program 3 when the thermostat stops calling for heat (the thermostat is open) the
following happens:

The burn rate decreases to Level 1 (low) and remains at this level until there is a call for heat by the thermostat
(the thermostat is closed), then resumes corresponding with the setting on the control panel.