3-6

M16 Microphone Amplifier

Revision MA2005-7

3.4.7

Channel Control Section Parameters

The Channel Control Section consists of the following features:

PFL Level

Channel Gain

Increment and Decrement Switches

Phase Reverse Switch

Pad Switch

Phantom Power Switch

High Pass Filter (Low Rumble Filter) Switch

Headphone Socket and Level Control

PFL Level

Any selection of the PFL switches on the front panel will route the se-
lected channel or channels to the PFL bus. A mono sum level indi-
cation is provided on the 20-segment PFL meter. The meter scale is
from -36dBu to +21dBu in 3dB increments with yellow LEDs as-
signed from -36dBu to +6dBu and red LEDs from +9dBu to +21dBu.

Channel Gain Indicator

The Channel Gain Indicator displays the gain setting for the selected
channel or group of channels. Gain is controlled in 5dB steps via the
Increment and Decrement switches to the right of the Gain Indicator.

NOTE: When multiple channels are selected, the ‘x’ indicator at
the bottom of the Channel Gain Indicator is illuminated.

Increment and Decrement Switches: Inc Dec

Use these controls to set the gain of the selected channel(s).

Pressing Inc increases the current gain setting by 5dB up to a max-
imum of 60dB

Pressing Dec decreases the current gain setting by 5dB to the min-
imum gain setting of 10dB

NOTE: The microphone amplifier employs circuitry to minimize
any unpleasant clicks when altering the gain setting.

Polarity Reverse Switch: Rev

Enabling the Rev switch reverses the polarity of the selected micro-
phone channel(s).

Pad Switch: Pad

Enabling the Pad switch attenuates the selected microphone chan-
nel(s) by -20dB. This is useful if feeding the M16 with very high line
level signals, although the M16 can accept +11dBu line level signals
at minimum gain (+10dB).

Advertising