APP-3

Revision MA2005-7

M16 Microphone Amplifier

M16: wiring for USB connector
Pin 1:

N/C

Pin 2:

DATA +

Pin 3:

DATA –

Pin 4:

COMMON

Shell:

COMMON

Important notes:

All CADAC products are Common Bonded. This is part of the
design procedure to ensure compliance with the European
EMCD (Electro Magnetic Compliance Directive): BSEN55103-1
(Emissions) and BSEN55103-2 (Immunity).

Common Bonding means a single conductive structure for all
reference, signal and power return currents.
COMMON = Safety Earth, GROUND, 0V, GND bonded together.

All ‘D sub’ connectors used for external connections should
be purchased with a conductive shell and the cable shield
MUST be bonded to the shell.