Caple CM400FA User Manual

Page 13

Advertising
background image

43

UK

• The machine is supplied with 6 metal plates

(thickness 1 mm) that are to be placed
between the guide and the sides of the unit.
This is to fill any excess space in the event
that the unit is more than 562 mm wide.

5.4

NUMBER OF SPACER
PLATES

• If necessary, insert the plates as described

above.

• Make sure that there is a distance (distance

B) of 558 mm between the corner pieces.

• Fix the guides to the coffee machine hous-

ing, tightening all of the screws.

• Make sure that the power cord comes out

from the rear of the housing.

• To prevent the machine from overheating,

make an opening in the back of the unit of at
least 300 mm x 100 mm, to allow air to cir-
culate.

• Insert the coffee machine into the unit, fitting

the guides on the machine level into the
guides previously fixed on the unit.
The guides should slide telescopically when
a light pressure is exerted on the front of the
coffee machine; if this is not the case, it is
necessary to check the distance between

BUILT-IN HOUSING

PLATES

Width

(mm/inc)

Thick.

(mm/inc)

562 / 22,13

19 / 0,748

0

564 / 22,2

18 / 0,708

1+1

566 / 22,28

17 / 0,669

2+2

568 / 22,36

16 / 0,629

3+3

• Remove the coffee machine from its pack-

aging and make sure that it is not damaged
in any way. Should the machine show any
signs of damage, do not proceed with instal-
lation and contact the retailer.

5.3

BUILT-IN
INSTALLATION

• Place the metal plate in position in the top

part of the coffee machine housing so that it
meets with the back section of the unit.

• Tighten the four screws.
• Place the two corner pieces with guides on

the flat surface in the unit, fixing them into
place exactly 90 mm from the unit’s front
edge.

• Insert the screws into the holes of the corner

pieces, but do not tighten them..

SCM5

SCM5_UK_Rev_2.qxp 23/01/2008 15.58 Pagina 43

Advertising