Stockweigh 550 eid and stockweigh link – Digi-Star StockWeigh 550 EID User Manual

Page 10

Advertising
background image

StockWeigh 550 EID and StockWeigh Link

6

LKNHLD

Lock-N-Hold
This feature continues to hold the Lock-On weight on the display
for an animal after it has stepped off the platform.
This allows the operator to place the animal on the weighing
platform, medicate, remove the animal from the platform and then
record the animal's weight after it has stepped off the platform.
The display will restart once another animal has stepped onto the
platform and exceeds 2.5% of the scale capacity. For example if
the scale capacity is set at 4000lbs (StockWeigh 3300), 100lbs is
required to reset the display. The indicator will return to normal
weighing after 5 minutes if no other animal steps on the weighing
platform. The [RECHECK] key can be used to return the indicator
to the weighing mode.

AUTOFF

Auto Off
This feature allows the operator to have the indicator
automatically shut itself OFF after either 15, 30, 45 or 60 minutes
of inactivity.
This feature will extend battery life on battery powered portable
scales. Prior to the scale shutting off, the message “

GOODBYE”

will be scrolled across the display for approximately 15 seconds.
Pressing a key on the indicator during this time will prevent the
unit from turning off and restart the internal shut-off timer.

LSTORE

Lock-On Store
This feature allows the user to configure how and when weighing
data is printed or sent to computer port and stored into memory on
the Indicator during animal weighing.
Data that is stored into memory is retrieved using “StockWeigh
Link” software.
Manual mode requires the operator to push [ON/RECORD] to
store and/or send the data for each animal.
The automatic mode allows the data to be stored and/or sent
either by pressing the [ON/RECORD] button, after the scale
“Locks-On” or when the animal steps off the platform.

OFF

Off
-

Indicator does not accept EID data.

-

Indicator does not store data to memory.

-

Sends data to computer port only when TAREAP or APRINT
are set to “ON”.

-

Set PRTFMT to select desired print format. See Appendix F.

MANPRT

Manual Print
-

Indicator does not accept EID data.

-

Indicator does not store data in memory.

-

Sends time, date and weight data to the computer port when
operator presses the [ON/Record] key.

-

Set PRTFMT to select desired print format. See Appendix F.

Advertising