Appendix E

Scoreboard Methods

There are ten scoreboard methods available. Methods one thru six sends numeric display data out
the RS232 port periodically while the other methods send a data stream as described below.

1.

Transmit numeric display data once per second.

2.

Transmit numeric display data two times per second.

3.

Transmit numeric display data three times per second.

4.

Transmit numeric display data at the A-D conversion rate.

5.

Transmit numeric display data at the display rate.

6.

Transmit numeric display data whenever there is a display weight change.

7.

Transmit status data string every second. Status data string includes weight, rotation
counter data, date and time.

8.

Transmit status data every five seconds. Status data string includes weight, rotation
counter data, date and time.

9.

Reserved.

10. Transmit EID data string every 2 seconds.

NOTES: When using SCOREM = 1, 2, 3, 4, 5, 6 and 9 be sure to set LSTORE = OFF, TAREAP = OFF

and APRINT = OFF to avoid corrupted data when transmitting scoreboard data and printing
scale data.

When using SCOREM = 7, 8 and 10, print data will not be corrupted by scoreboard data.