Stockweigh 550 eid and stockweigh link – Digi-Star StockWeigh 550 EID User Manual
Page 12
StockWeigh 550 EID and StockWeigh Link
8
AUTEID
Automatic EID
-
Indicator accepts EID data.
-
Message alerts operator if EID data is missing.
-
Sends EID, time, date and weight data to the computer port
and stores the CSV in memory when the scale “Locks-On” or
when the animal steps off the platform.
-
Set LSSEND to select when data is printed.
-
Print format is EID print format. See Appendix F.
-
Data is stored in EID data format. See Appendix F.
-
If LSSEND is “ON” and EID is not read, press [ON/RECORD]
to print data.
-
If LSSEND is “OFF” and EID is not read, time, date and weight
data will print when the animal steps off the platform.
-
If ESTORE is “OFF”, data is not stored into indicator memory.
MANCHK
Manual Check
-
Indicator accepts EID data.
-
Message alerts operator if EID data is missing. Operator must
press [ON/RECORD] to print and store data with or without
EID.
-
Sends EID, time, date and weight data to the computer port
and stores the comma-separated values (CSV) in memory
when operator presses the [ON/Record] key.
-
Print format is EID print format. See Appendix F.
-
Data is stored in EID data format. See Appendix F.
-
If ESTORE is “OFF”, data is not stored into indicator memory.
AUTCHK
Automatic Check
-
Indicator accepts EID data.
-
Message alerts operator if EID data is missing. Operator must
press [ON/RECORD] to print and store data without EID.
-
Sends EID, time, date and weight data to the computer port
and stores the (CSV) in memory when EID data is read and
the scale locks-on or when the animal steps off the platform.
-
Set LSSEND to select when data is printed.
-
Print format is EID print format. See Appendix F.
-
Data is stored in EID data format. See Appendix F.
-
If ESTORE is “OFF”, data is not stored into indicator memory.