Digi-Star StockWeigh 550 EID User Manual

Page 9

Advertising
background image

Operators Manual

D3645

5

Changing Options Using Long Form Setup

1. Enter the Long Form Setup by holding [Net-Gross] and pushing [ON/Record] for three

seconds.

2. Press [On/Record] to advance to the desired parameter.
3. Press [Net/Gross] to advance to the proper setting.
4. Press [On/Record] to save setting and advance to the next parameter.
5. Hold [Tare] and press [On] to return to indicator operation.

Default Settings

Default settings for the indicator are as follows:

ZTRACK

ON

date

(SET)

W MTHD

4

TareAP

off

LOCKON

8

l prt

off

LKNHLD

Off

scorem

0

AUTOFF

off

aprint

off

LSTORE

AUTEID

prtfmt

Auto

Lssend

OFF

c1 dly

off

Estore

ON

c2 dly

off

Izero

on

count

1

EIDAUT

0FF

arange

on

TOME F

24 HR

lb-kg

lb

TIME

(SET)

cap

40000

Date F

2

These parameters can be selected, de-selected or adjusted to fit the way you use the scale. See
below for descriptions.

ZTRACK

Zero Tracking
If “ON”, the scale will adjust for small weight variances of up to 5lbs
in the Lock-On weigh method. This allows the scale to compensate
for such things as mud or snow accumulation on the scale platform.

W MTHD

Weigh Method
Weigh method allows the operator to adjust how much processing
or number-crunching the scale processor does to the load cell data
before displaying the weight. See Appendix “B” for details. Select
weigh method #4 “Lock-On” for animal weighing.

LOCKON

Lock-On
Available settings are 1 thru 9. A low value, such as a 1 or 2,
allows the system to be more sensitive to animal motion. A high
value, such as an 8 or 9, allows the scale to lock on faster. Use
the lowest setting that still allows the system to lock on
consistently.

Advertising