Digi-Star StockWeigh 550 EID User Manual
Page 9
![background image](/files/781487/content/doc009.png)
Operators Manual
D3645
5
Changing Options Using Long Form Setup
1. Enter the Long Form Setup by holding [Net-Gross] and pushing [ON/Record] for three
seconds.
2. Press [On/Record] to advance to the desired parameter.
3. Press [Net/Gross] to advance to the proper setting.
4. Press [On/Record] to save setting and advance to the next parameter.
5. Hold [Tare] and press [On] to return to indicator operation.
Default Settings
Default settings for the indicator are as follows:
ZTRACK
ON
date
(SET)
W MTHD
4
TareAP
off
LOCKON
8
l prt
off
LKNHLD
Off
scorem
0
AUTOFF
off
aprint
off
LSTORE
AUTEID
prtfmt
Auto
Lssend
OFF
c1 dly
off
Estore
ON
c2 dly
off
Izero
on
count
1
EIDAUT
0FF
arange
on
TOME F
24 HR
lb-kg
lb
TIME
(SET)
cap
40000
Date F
2
These parameters can be selected, de-selected or adjusted to fit the way you use the scale. See
below for descriptions.
ZTRACK
Zero Tracking
If “ON”, the scale will adjust for small weight variances of up to 5lbs
in the Lock-On weigh method. This allows the scale to compensate
for such things as mud or snow accumulation on the scale platform.
W MTHD
Weigh Method
Weigh method allows the operator to adjust how much processing
or number-crunching the scale processor does to the load cell data
before displaying the weight. See Appendix “B” for details. Select
weigh method #4 “Lock-On” for animal weighing.
LOCKON
Lock-On
Available settings are 1 thru 9. A low value, such as a 1 or 2,
allows the system to be more sensitive to animal motion. A high
value, such as an 8 or 9, allows the scale to lock on faster. Use
the lowest setting that still allows the system to lock on
consistently.