Operating modes, Operation (cont.) – MovinCool Office Pro W20 User Manual

Page 20

Advertising
background image

20

OPERATION (cont.)

Operating Modes

The Office Pro W20 can be operated in two modes, FAN ONLY and COOL. When

in FAN ONLY mode, the unit circulates the surrounding air. When in COOL mode,

the compressor is operated and cool air is circulated.
1. COOL Mode

Once the compressor has been disengaged for more than 120 seconds, the

unit operates in FAN ONLY mode for approximately 5 seconds before the

compressor re-engages.

2. Temperature Control

The room temperature thermistor monitors the inlet temperature versus set

point temperature and switches the unit automatically between COOL and

FAN ONLY modes.

3. Fan Mode Control DIP Switch

The fan mode control DIP switch determines whether the fan continues to

operate or stop when the compressor cycles off. (Set point temperature below

the inlet air or room temperature.) The unit has been preset at the factory for

continuous fan operation.
Note: If you want to change the fan mode operation (from OPERATE to

STOP), contact your MovinCool reseller.

4. Temperature Scale Display DIP Switch

The temperature scale display DIP switch changes the temperature(s) that are

displayed to either °C or °F. The unit has been preset at the factory to display

the temperature(s) in °F.
Note: If you want to change the temperature scale display (°F to °C), contact

your MovinCool reseller.

Advertising
This manual is related to the following products: