Inspection & maintenance (cont.), Water regulating valve (cont.) – MovinCool Office Pro W20 User Manual

Page 32

Advertising
background image

32

INSPECTION & MAINTENANCE (cont.)

Water Regulating Valve (cont.)

Adjustment of Water Regulating Valve Setting (cont.)

7. Write the value setting with a permanent marker on the adjustment record

table on the inside panel of the unit.

Note: Recording the value setting is very important for reference when making

future adjustments.

Valve Setting Guide Table

Adjustment Record (Example)

CAUTION: Do not forget to write down the value setting with a

permanent marker on the adjustment record table. This is the only

way to know the current valve setting. It is difficult to exactly adjust

the valve without the current valve setting. Failure to adjust the

valve may damage the unit and void the warranty. Contact a

qualified technician for details.

SETTING

DIRECTION OF

VALVE ROTATION

NUMBER OF

ROTATION

VALVE OPENING

TEMPERATURE

MINIMUM WATER

TEMPERATURE

A

Clockwise

4

72 °F (22 °C)

40 °F (4.4 °C)

B

3

75 °F (24 °C)

47 °F (8 °C)

C

2

79 °F (26 °C)

54 °F (12 °C)

D

1

82 °F (28 °C)

61 °F (16 °C)

E

Default Setting Point

-

86 °F (30 °C)

68 °F (20 °C)

F

Counterclockwise

1

90 °F (32 °C)

72 °F (22 °C)

G

2

94 °F (34 °C)

75 °F (24 °C)

H

3

96 °F (36 °C)

79 °F (26 °C)

I

4

100 °F (38 °C)

83 °F (28 °C)

NO.

SETTING DATE

SETTING

NO.

SETTING DATE

SETTING

0

-

E

11

Dec. 10, 2010

B

Apr. 10, 2011

D

Aug. 10, 2011

G

10

21

Advertising