4 scsi termination – OpenEye GraniteRack 3U User Manual

Page 32

Advertising
background image

Getting Started

2-10

2.4 SCSI Termination

Two 68-pin wide SCSI connectors are provided on the back of the enclosure

for connecting the array to the system. These connectors are used in one of

two ways:

If the disk array is the only external SCSI device, or is the last external

device in a daisy-chained configuration, connect the incoming cable (the

one which is attached to the SCSI adapter) to the Host A & B in connec-

tor and install the external SCSI Terminator on the Host A & B out

connector.

If the array is to be placed in the middle of a daisy-chained configuration,

connect the incoming cable (the one which is attached to the SCSI

adapter) to the Host A & B in connector and connect the outgoing cable

(the one which continues on to other devices) to the Host A & B out

connector. In this case, no terminator is required at the disk array but

the last device in the daisy chain must have a terminator.

Correct SCSI termination procedures require that the last devices on the

SCSI bus be terminated. If the last device is not terminated, or if devices

other than the last are terminated, erratic SCSI bus performance may occur.

Typically, the system or host adapter (SCSI card inside the PC) is the first

device and is already terminated. When installing the disk array on a SCSI

Advertising