RJS Inspector D4000 Laser (FIRMWARE version A.05 and Earlier) User Manual

Page 16

Advertising
background image

Model L1000 Laser Inspector

TM

Operator

s Guide

RJS, Minneapolis, MN

002-5568

10

5.2 Setup

Select Setup (from the Main Menu) to set various system parameters:

D/bility Warning

D


Select an ANSI decodability grade to use in your analysis (See Appendix G for an explana-
tion of the grades.)

A warning message will be produced for the selected grade or any lower grades:

B C D F NONE

Press Select to scroll the choices for warning threshold grade

Press Enter to initiate processing for that option


If NONE is selected, the decodability grade will not be used to trigger a warning message.
However, the decodability grade will be calculated and available for viewing.

The next selection allows selection from a range of UPC/EAN symbol magnifications:

UPC/EAN tol.

90 - 115% Mag.


The magnifications selections are:
(See Appendix D for an explanation of magnifications.)

80 - 89 % Mag

90 - 115 % Mag

116 - 150 % Mag

151 - 200 % Mag

Advertising
This manual is related to the following products: