Table f-2, (parameters checked for each symbology) – RJS Inspector D4000 Laser (FIRMWARE version A.05 and Earlier) User Manual

Page 51

Advertising
background image

Operator

s Guide

Appendix F

002-5568

RJS, Minneapolis, MN

45

Table F-2, (Parameters Checked for Each Symbology)


Symbology

Ratio

ICG

Data
Character

Mod
Check

Tolerance

AIAG B-1

2.2-3.2

.5X-8X

STD CODE 39

N/A

((12R-8)/81)X

AIAG B-3/4/5


2.8-3.2


.5X-8X

$/+%
Not Allowed


N/A


((12R-8)/81)X

LOGMARS

2.2-3.0

.5X-8X

STD CODE 39

N/A

((12R-8)/81)X

ANSI 3 of 9

2.2-3.0

.5X-8X

STD CODE 39

N/A

((12R-8)/81)X

3 of 9 w/43

2.2-3.0

.5X-8X

STD CODE 39
4 CHARS Min

MOD 43

((12R-8)/81)X

HIBC 3 of 9

2.2-3.0

.5X-8X

STD CODE 39
Min 2 CHARS
1ST. = "+"

MOD 43

((12R-8)/81)X

ANSI 2 of 5

2.2-3.0

N/A

N/A

N/A

((18R-21)/80)X

Case Code

2.3-2.9

N/A

3 Data Chars
Min.

MOD 10

((18R-21)/80)X

Code 128

N/A

N/A

N/A

MOD 103

.35X

128 Case Code

N/A

N?A

16 Data Char.
Format Check

Mod 10
Mod 103

.35X

UPC/EAN

N/A

N/A

N/A

MOD 10
See Note
3

See Note 5

Codabar
Variant

2.2-3.0

.5X-8X

STD
CODABAR

N/A

((5R-8)/20)X

Code 93

N/A

N/A

STD CODE 93

C&K

.35X

Advertising