Analog camera, Analog camera select, Dome protocol – ARM Electronics DVRHD OSD User Manual

Page 29: Dome id, Camera title

Advertising
background image

OSD Setup Manual

28

Camera Setup

ʳ ʳ ʳ ʳ ʳ ʳ ʳ ʳ ʳ ʳ

The items in the Camera Setup menu enable users to set camera parameters, including

camera title, dome protocol and ID for each connected camera. There will be separate

menus for analog cameras and IP cameras. Please refer to <Analog Camera> section if the

connected camera is an analog camera, or refer to <IP Camera> section when the

connected camera is an IP camera.

< Analog Camera >

If the connected camera is an analog camera, please continue with this section. Items in

this menu are described in the following subsections.

Analog Camera

Analog Camera Select
Dome Protocol
Dome ID
Camera Title
Covert
Brightness
Contrast
Saturation
Hue

CH1

None

0

CH1

No

0
0
0
0

„ Analog Camera Select

This item is used to select a camera for setting the parameters. The related

settings will follow the selected camera, such as dome protocol and camera title.

Move the cursor to <Analog Camera Select> and press ENTER, then select a

channel using UP / DOWN keys.

„ Dome Protocol

If the connected camera is a dome camera, select the communication protocol

associated with the dome camera using ENTER and Direction keys. The default is

set to <None>.

„ Dome ID

This item is used to assign an ID number to the selected dome camera. Note that

ID number must match the ID address set by the dome camera.

„ Camera Title

This item allows the users to change the title of each connected camera. By default,

the titles of cameras are numbered from 1 through 16 respectively. The title will be

displayed on the screen after the changes of the titles are set.