OSD Setup Manual

46

-

Sensitivity

This item is used to set the sensitivity of detection grids for the camera. A

greater value indicates more sensitive motion detection. A motion alarm

will be triggered once the amount of motion detected exceeds the

Threshold value.

Move the cursor to <Sensitivity> and press ENTER, and then use UP/

DOWN keys to adjust the value. The value is increased by 4% increment.

-

Block Threshold

<Block Threshold> indicates the motion alarm triggered level; select from

<1> to <16>. Selecting <1> means the DVR will trigger the alarm when

one grid is detected; and selecting <16> means the DVR will trigger the

alarm when 16 grids are detected. Move the cursor to <Block Threshold>

and press ENTER, and then use UP / DOWN keys to adjust the value.

„ Alarm In

This item allows users to enable/ disable alarm input detection. According to users’

application, select <N/O> (Normal Open) or <N/C> (Normal Close) to enable the

alarm input detection, or select <OFF> to disable the detection.

If <N/C> is selected without installing any device, an alarm will be triggered and the

Event Icon will always display on the monitor until the selection is changed to

<N/O> or <OFF>, or when a device is installed.

„ Alarm Out

This item allows users to enable / disable the alarm output on the selected channel

to activate the relay. The signal can be a light or siren to caution an alarm event.

Select <ON> to enable the alarm output, or <OFF> to disable.