Operation and Maintenance

Downgrading from Output Server 2 to Output Server 1

Downgrading from Output Server 2 to Output Server 1

It is possible to downgrade from Output Server 2, back to Output Server 1, if required. iTX
stores the configuration data for both versions of the service separately, so that after rolling
back to Output Server 1 you will be reverted to its own configuration settings.

IMPORTANT

After downgrading back to the Output Server 1 service, you must roll
back the AJA video card drivers on your playout server to v7.4.0.49.

You can verify the version of the currently installed drivers by accessing
the AJA Corvid SDI I/O Properties or AJA Kona SDI I/O Properties window
from Device Manager. See

Required Software and Driver Versions

on

page 5 for more information.

To downgrade from Output Server 2 back to Output Server 1:

1 Access and open the iTX Installer files.

2 Right-click the

Setup.exe

file and select

Run as administrator

.

3 Click SELECT SOFTWARE.

4 Expand the Playout section

5 Uncheck Output Server 2

6 Click OK to return to the iTX Installer dialog.

7 Click CONTINUE. Allow Output Server 2 to uninstall completely.

8 Click SELECT SOFTWARE.

9 Expand the Playout section

10 Check Output Server 1.

11 Click OK to return to the iTX Installer dialog.

12 Click CONTINUE to reinstall Output Server 1.