Configurator

CP Output Set

5−83

VM 3000 Installation and Operating Manual

Remember that a CP 3000 and CP 3030 panel can display four−character mnemonics, while the CP 3008, and CP
3800 can display eight−character mnemonics.

e.

Optionally, select a Level Set name.

The Level Set column should be used when multiple switchers are in the system and you want the control panels
to control and status more than one switcher. See page 5−97.

The source of these names is the CP Level Set tables (page 5−55).

f.

Optionally, enter a Button number. This is used to assign Expansion Panel buttons to individual outputs:

CP 3010 Expansion Panel − Outputs are normally assigned to the CP 3010 TAKE button dynamically, by the
operator (see page 6−24). However, by entering an expansion button number from 1 to 160 (8 buttons x 20 pages)
in the Button column, the output will be assigned permanently to the desired button. Such assignments cannot be
changed using the panel itself.

Note: If an output is permanently assigned to a CP 3010 button, but that output is later removed from the
CP Output table and the new set downloaded, the CP 3010 will continue to display the name of the out-
put until the output is manually deleted. This is done by selecting an output that is not defined and press-
ing the appropriate TAKE key on the expansion panel.

CP 3800 − When in Multiple Destination mode, CP 3800 outputs can be assigned to the soft keys dynamically,
by the operator (see page 6−34). However, by entering a soft key button number from 1 to 80 (8 buttons x 10 pages)
in the “Button” column the output will be assigned permanently to the desired button. Such assignments cannot
be changed using the panel itself.

CP 3810 Expansion Panel − By entering an expansion button number from 1 to 80 (8 buttons x 10 pages) in the
Button column, the output will be assigned permanently to the desired button.

When finished, skip to Step 20.

10.

CP 320, CP 328, CP 3808, CP 3830, CP 3830P

a.

Enter the desired Category. This can be done by double−clicking on the appropriate field in the Category column;
this will open a pull−down menu of categories. Click on a category and press ENTER.

The 16−category factory default set used for the CP 3808 panel is as follows:

Default sets may vary —
confirm by creating a new set!

VTR

CAM

SAT

EJ

VCR

NET

REM

FILM

Studio

MISC

AUX

FS

CGEN

TEST

PTCH

STILL

The 16−category factory default set used for CP 320 and CP 328 panels is as follows:

VTR

CG

NET

VCR

CAM

AUX

EJ

SS

REM

FILM

PTCH

STU

TEST

SAT

FS

MISC