Appendix K

Redundant VM/SI 3000 Manual Changeover

In a redundant VM/SI−3000 installation, changeover should occur automatically in the event of a fault. To make the change-
over manually, check the front panel “Active” LED to see which unit is active and which is in standby. To make the change-
over, press the “Activate” button on the standby unit.

Figure K−1. VM 3000 changeover button (SI 3000 is similar).

Changeover

button

UP

DOWN

NEXT

SELECT

ACTIVE

FAULT

FAULT

CLEAR

ACTIVATE

POWER

ALARM

PROBE

Note 1: Only late−model VM 3000 Control Processors can be operated in redundant mode. Please contact Grass
Valley for additional information.

Note 2: Automatic changeover is not available for the party line port or the VGA port.