Configuring the level 2r storage system, Prerequisites for initial configuration – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual

Page 120

Advertising
background image

120

K2 Storage System Instruction Manual

September 6, 2006

Chapter 4 Installing the Level 2R Storage System

Configuring the Level 2R storage system

Use the topics in this section to do the initial configuration of the Level 2R storage
system.

“Prerequisites for initial configuration” on page 120

“Defining a new K2 Storage System” on page 121

“Configuring the media server - Part 1” on page 123

“Configuring RAID” on page 125

“Creating a new file system” on page 132

“Configuring the media server - Part 2” on page 133

“Configuring the redundant media server” on page 136

Prerequisites for initial configuration

Before beginning your initial configuration, make sure the devices of the K2 Storage
System meet the following prerequisites. Refer to sections earlier in this manual for
detailed information. Also refer to

Chapter 8, “Description of K2 Storage Devices”

.

Devices

Prerequisite for Level 2R configuration

Control point PC

Ethernet cable connected
Control Point software installed
Control network IP address assigned
Network communication over the control network with all other K2
devices
Power on

Ethernet switch

Ethernet cables connected
Control network IP address assigned
VLANs set up
Trunks set up
Power on

K2 Media Server

Ethernet cables connected
Fibre Channel cable connected
Redundant servers connected by serial cable
Software installed, as from the factory, including QuickTime 7
Control network IP address assigned
Power on

L2 RAID chassis

Fibre Channel address ID assigned to RAID controller(s)
Fibre Channel cable(s) connected
Ethernet cable(s) connected
Power on

L2 RAID Expansion
chassis
(optional)

Chassis address assigned (for Fibre Channel)
Fibre channel cable(s) connected
Power on

Advertising
This manual is related to the following products: