Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual

Page 230

Advertising
background image

230

K2 Storage System Instruction Manual

September 6, 2006

Chapter 6 Installing the Level 3R Storage System

represented by the single “Controller” node)

The Bind LUN dialog box opens showing all unbound disks for the controller
listed in the Available Disk list.

NOTE: Leave Full Bind selected. Do not uncheck it.

b. In the

LUN TYPE

drop down box, select

RAID 5

. If specified by your system

design, RAID 6 is also supported. Refer to the Nearline chapter for more
information on RAID 6.

c. In the Available Disks box, select five contiguous disks at the top of the list.

(TIP: Use ‘shift-click’ or ‘control-click’ to select disks.).

d. Click the add (arrow) button to add disks to the Selected Disks list.

NOTE: As an aid in identifying a disk module’s physical location, select it in the
Selected Disks list, then click

Identify Disks.

This causes the disk drive light to flash.

e. Click

OK

to close the Binding LUN dialog box and begin the binding process.

The Progress Report dialog box opens, showing the status of the binding
process.

Advertising
This manual is related to the following products: