Loading raid controller microcode, Downloading disk drive firmware – Grass Valley K2 Storage System Instruction Manual v.3.1 User Manual

Page 370

Advertising
background image

370

K2 Storage System Instruction Manual

September 6, 2006

Chapter 12 Administering and maintaining the K2 Storage System

6. Restart the K2 Media Server.

Loading RAID controller microcode

You might be instructed in K2 release notes to upgrade the RAID Controller
microcode on the RAID chassis. This allows you to take advantage of the RAID
enhancements and benefit from improved reliability.

To upgrade RAID Controller microcode, do the following:

1. In Storage Utility, right-click a controller in the tree view, then select

Advanced |

Load Controller Microcode

. Redundant controllers that share the same set of disks

are automatically selected and upgraded as a pair.

The Open File dialog box appears.

2. In the Open File dialog box, browse to the latest controller microcode file for your

controller, select the file, and click

OK

.

3. The Progress Report window appears showing the microcode upgrade task and the

percentage completion.

4. On 100% completion, power cycle the RAID controller chassis, then restart the K2

Media Server.

Downloading disk drive firmware

You might be instructed in K2 release notes to upgrade disk drive firmware. This
allows you to take advantage of the disk drive enhancements and benefit from
improved performance and reliability.

Advertising
This manual is related to the following products: