Maintenance, Battery, Battery storage – Polaris 2014 BRUTUS Owner's Manual User Manual

Page 114: Battery charging

Advertising
background image

112

MAINTENANCE

Battery

Battery Storage

Whenever the vehicle is not used for a period of three months or more, remove the battery

from the vehicle, ensure that it's fully charged, and store it out of the sun in a cool, dry place.

Check battery voltage each month during storage and recharge as needed to maintain a full

charge. POLARIS recommends maintaining battery charge by using a POLARIS Battery

Tender charger or by charging about once a month to make up for normal self-discharge.

Battery Tender can be left connected during the storage period, and will automatically charge

the battery if the voltage drops below a pre-determined point. See page 119

for the part

numbers of POLARIS products.

Battery Charging

The following battery charging instructions apply only to the installation of a sealed battery.

Read all instructions before proceeding with the installation of this battery. The sealed

battery is already filled with electrolyte and has been sealed and fully charged at the factory.
Never pry the sealing strip off or add any other fluid to this battery.
Always keep a sealed battery fully charged. Since the battery is sealed and the sealing strip

cannot be removed, you must use a voltmeter or multimeter to measure DC voltage.

WARNING! An overheated battery may explode, causing severe injury or death. Always watch
charging times carefully. Stop charging if the battery becomes very warm to the touch. Allow it to cool
before resuming charging.

For a refresh charge, follow all instructions carefully.
1. Check the battery voltage with a voltmeter or multimeter. A fully charged battery will

register 12.8 V or higher.

2. If the voltage is less than 12.8 volts, recharge the battery at 1.2 amps or less until battery

voltage is 12.8 or greater.

3. When using an automatic charger, refer to the charger manufacturer's instructions for

recharging. When using a constant current charger, use the guidelines below for

recharging.

Always verify battery condition before and 1-2 hours after the end of charging.

State of

Charge

Voltage

Action

Charge Time

(Using constant current

charger @ standard amps

specified on top of battery)

100%

12.8-13.0 volts

None, check at 3 mos. from date of

manufacture

None required

75%-100%

12.5-12.8 volts

May need slight charge, if no

charge given, check in 3 months

3-6 hours

50%-75%

12.0-12.5 volts

Needs charge

5-11 hours

25%-50%

11.5-12.0 volts

Needs charge

At least 13 hours, verify

state of charge

0%-25%

11.5 volts or less

Needs charge with desulfating

charger

At least 20 hours

Advertising