Maintenance, Spark arrester – Polaris 2014 BRUTUS Owner's Manual User Manual

Page 97

Advertising
background image

95

MAINTENANCE

Spark Arrester

Failure to heed the following warnings while servicing the spark arrester could result in serious injury or
death.

Do not perform service on the spark arrester while the system is hot. Exhaust system temperatures can
reach 1000° F. Allow components to cool sufficiently before proceeding.

Remove any combustible materials from the area.

Wear eye protection and gloves.

Do not stand behind or in front of the vehicle while purging.

Never run the engine in an enclosed area. Exhaust can cause loss of consciousness or death in a very
short time.

Never go under the vehicle while it's inclined.

Use the following procedure to periodically purge accumulated carbon from the exhaust

pipe.
1. Remove the arrester clean-out plug located on

the bottom of the muffler.

2. Place the transmission in Park. Start the

engine.

3. Press the brake pedal and then press the treadle

pedal to increase engine RPM. Purge

accumulated carbon from the system by

momentarily revving the engine several times.

4. If carbon is expelled, partially cover the

exhaust outlet and rap on the pipe around the

clean-out plug while revving the engine several

more times.

5. If particles are still suspected to be in the

muffler, elevate the rear of the vehicle one foot

higher than the front. Block the wheels.

6. Repeat steps 3 and 4 until no more particles are expelled when the engine is revved.
7. Stop the engine. Allow the arrester to cool.
8. Reinstall the arrester plug and remove the partial outlet cover.

WARNING

Clean-Out Plug

Exhaust Outlet

Advertising